Tethered X-ray detectors for OR Technology X-ray systems
XenOR 43-139F [to the product information]
Active area 43 x 43 cm (17" x 17"), tethered, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, Pixel pitch 139 µm, exposure control with AED, weight approx. 4 kg (without cable)
The XenOR 43-139F is used in the following X-ray systems:
Amadeo V-DR, Amadeo V-DR mini II, Amadeo V-DR nano II
XenOR 43CL [to the product information]
Active area 43.4 x 43.4 cm (17.0" x 17.0"), tethered, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator (thick version for higher DQE), exposure control with AED, pixel pitch 154 µm, weight 3.9 kg (8.6 lbs.)
The XenOR 43CL is used in the following X-ray systems:
Medici, Amadeo V-DR, Amadeo V-DR mini II, Amadeo V-DR nano II
XenOR 35CL [to the product information]
Active area 43.3 x 35.5 cm (17" x 14"), tethered, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator (thick version for higher DQE), pixel pitch 154 µm, exposure control with AED, weight 3.2 kg (7 lbs.)
The XenOR 35CL is used in the following X-ray systems:
Medici, Amadeo V-DR, Amadeo V-DR mini II, Amadeo V-DR nano II
Varex XRpad2 4343F[to the product information]
Active area 43.2 x 43.2 cm (17.0" x 17.0"), tethered, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, pixel pitch 100 µm, exposure control with AED, weight 3.8 kg (8.4 lbs.)
The Varex XRpad2 4343F is used in the following X-ray systems:
Medici, Amadeo V-DR, Amadeo V-DR mini II, Amadeo V-DR nano II
Varex PaxScan 4343RC [to the product information]
Active area 42.4 x 42.4 cm (16.7" x 16.7"), tethered, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, pixel pitch 139 µm, exposure control with AED, weight approx. 3.76 kg (8.3 lbs.)
The Varex PaxScan 4343RC is used in the following X-ray systems:
Medici, Amadeo V-DR
Canon ETD FDXA4343R/A [to the product information]
Active area 42.6 x 42.5 cm (16.8" x 16.7"), tethered, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, Pixel pitch 140 µm, exposure control with AED, weight approx. 4,3 kg
The Canon ETD FDXA4343R/A is used in the following X-ray systems:
Medici, Amadeo V-DR, Amadeo V-DR mini II, Amadeo V-DR nano II
Wireless X-ray detectors for OR Technology systems
XenOR 35-100WF [to the product information]
Active area 35,5 x 43 cm (14" x 17"), first-class wireless X-ray detector in cassette format based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, large-capacity battery with a runtime of more than 8h, automatic exposure detection (AED), weight (3.7 kg), pixel pitch of 100 μm
The XenOR 35-100WF is used in the following X-ray systems:
Medici, Amadeo V-DR, Leonardo DR nano, Leonardo DR mini II
XenOR 33-100W-flex [to the product information]
Active area 25 x 33 cm (10" x 13"), compact and robust X-ray detector with flexible layer (no glass) incl. Csl scintillator specially developed for use in equine medicine, narrow edges of only approx. 7 mm on 2 sides, automatic exposure detection (AED), reduced weight (2 kg), picxel pitch 100 µm
The XenOR 33-100W-flex is used in the following X-ray systems:
Amadeo V-DR, Leonardo DR nano, Leonardo DR mini II
XenOR 43CW [to the product information]
Active area 43.4 x 43.4 cm (17.0" x 17.0"), portable wireless detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator (thick Version for higher DQE), pixel pitch 154 µm, exposure control with AED, weight 4.1 kg (9.0 lbs.)
The XenOR 43CW is used in the following X-ray systems:
Medici
XenOR 35CW [to the product information]
Active area 35.5 x 43.4 cm (13.9" x 17.0"), portable wireless detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator (thick version for higher DQE), pixel pitch 154 µm, exposure control with AED, weight 3.7 kg (8.2 lbs.)
The XenOR 35CW is used in the following X-ray systems:
Medici, Leonardo DR nano, Leonardo DR mini II
XenOR 24CW [to the product information]
Active area 24.,6 x 30.7 cm (9.5" x 12.0"), portable wireless detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator (thick Version for higher DQE), pixel pitch 120 µm, exposure control with AED, weight 2.3 kg (5 lbs.)
The XenOR 24CW is used in the following X-ray systems:
Medici, Leonardo DR mini II, Leonardo DR pico
Varex XRpad2 4343W [to the product information]
Active area 43.2 x 43.2 cm (17" x 17"), wireless, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, pixel pitch 100 µm, exposure control with AED, weight approx. 3.8 kg (8.4 lbs.)
The Varex XRpad2 4343W is used in the following X-ray systems:
Medici
Varex XRpad2 4336 [to the product information]
Active area 35.0 x 42.6 cm (13.8" x 16.8"), portable wireless detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, pixel pitch 100 µm, exposure control with AED, weight 3.1 kg (6.8 lbs.)
The Varex XRpad2 4336 is used in the following X-ray systems:
Medici, Leonardo DR mini II, Leonardo DR nano
Varex XRpad2 3025 [to the product information]
Active area 29.8 x 24.8 cm (11.8" x 9.8"), portable wireless detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, pixel pitch 100 µm, weight 1.8 kg (6.8 lbs.)
The Varex XRpad2 3025 is used in the following X-ray systems:
Medici, Leonardo DR mini II, Leonardo DR pico
Varex PaxScan 4336Wv4 [to the product information]
Active area 33.9 x 42.4 cm (13.3" x 16.7"), wireless, detector based on amorphous Silicon (a-Si) with Caesium Iodide (CsI) scintillator, pixel pitch 139 µm, exposure control with AED, weight approx. 3.0 kg (6.6 lbs.)
The Varex PaxScan 4336Wv4 is used in the following X-ray systems:
Medici, Leonardo DR mini II, Leonardo DR nano
Varex PaxScan 4343W [to the product information]
Active area 42,4 x 42,4 cm (16,7" x 16,7"), improved ergonomics including hand grips, inductive charging, ingress Protection rating of IP68, reduced weight (3.1 kg / 3.3 kg), pixel pitch 139 µm, exposure control with AED
The Varex PaxScan 4343W is used in the following X-ray systems:
Medici